DNA Clean & Concentrator MagBead Kit
Read or write a reviewPCR cleanup / Magnetic bead purification
Catalog category candidate. Experimental interchangeability has not been validated.
BIOLOGICAL DOMAIN
Start with the right input. Explore extraction, cleanup and enrichment by nucleic acid and sample workflow.
Enzymatic PCR cleanup, Agarose digestion, High molecular weight DNA extraction
301 products ›mRNA enrichment, RNA extraction, RNA cleanup
139 products ›Cell lysis
5 products ›Magnetic capture beads, Precipitation reagents, Protein removal reagents
15 products ›Slide-mounted tissue sampling reagents, Deparaffinization reagents
3 products ›Urine stabilization reagents, DNA and RNA stabilization
9 products ›General sample nucleic acid extraction, Viral nucleic acid extraction, FFPE nucleic acid extraction
61 products ›Yeast cell wall digestion
4 products ›PCR cleanup / Magnetic bead purification
Catalog category candidate. Experimental interchangeability has not been validated.
PCR cleanup / Spin-column purification / Reported capacity 100 µg DNA
Catalog category candidate. Experimental interchangeability has not been validated.
PCR cleanup / Spin-column purification / Reported capacity 25 µg DNA
Candidate category only. Match the stated sample, material, capacity, geometry and required output before comparison; experimental interchangeability is not established.
PCR cleanup / Spin-column purification / Reported capacity 5 µg DNA
Candidate category only. Match the stated sample, material, capacity, geometry and required output before comparison; experimental interchangeability is not established.
PCR cleanup / Spin-column purification / Reported capacity 500 µg DNA
Candidate category only. Match the stated sample, material, capacity, geometry and required output before comparison; experimental interchangeability is not established.
Genomic DNA cleanup / Spin-column purification
Spin-column cleanup and concentration of genomic DNA and DNA from enzymatic reactions; 40 µg capacity. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
Genomic DNA cleanup / Spin-column purification
Glass-fiber spin columns clean previously extracted genomic and other DNA; 70 bp to 20 kb fragment range. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
Gel extraction / Spin-column purification
Maxi spin-column extraction of DNA from agarose gel or enzymatic reactions; 200 µg capacity. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
Gel extraction / Spin-column purification
Spin-column recovery of DNA fragments from agarose gel. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.

DNA size selection / Magnetic bead purification
Size cutoff depends on bead ratio and sample composition.
General sample nucleic acid extraction / Spin-column purification
Sequential spin-column DNA and RNA co-extraction from blood, cells and tissue; separate DNA and RNA eluates. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
DNA and RNA stabilization / Liquid preservation reagents
Candidate category only. Match the stated sample, material, capacity, geometry and required output before comparison; experimental interchangeability is not established.
DNA and RNA stabilization / Liquid preservation reagents
Requires review: exact composition, calibration, formulation, kit or hardware compatibility, or regulatory identity is not fully established by the captured manufacturer description. Shared function is insufficient for substitution.
General sample nucleic acid extraction / Spin-column purification
Sequential spin-column DNA and RNA co-extraction with an additional protein recovery workflow. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.

Genomic DNA extraction / Spin-column purification
Same application category. Compare formulation, input requirements and protocol before substitution.

Fecal and soil DNA extraction / Spin-column purification
Same application category. Compare formulation, input requirements and protocol before substitution.
Genomic DNA extraction / Spin-column purification
Spin-column genomic DNA extraction from dried blood spots. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
Genomic DNA extraction / Magnetic bead purification
Magnetic-bead DNA isolation from dried blood spots. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
Genomic DNA extraction / Spin-column purification
Spin-column extraction of genomic DNA from dried blood spots and small blood, urine or saliva samples. Candidate for the specified application; follow the manufacturer protocol and validate sample and instrument compatibility.
mRNA enrichment / Magnetic bead purification
Candidate for the stated function. Confirm substrate, formulation, reaction conditions and application before substitution.
mRNA enrichment / Magnetic bead purification
Candidate for the stated function. Confirm substrate, formulation, reaction conditions and application before substitution.
mRNA enrichment / Magnetic bead purification
Candidate for the stated function. Confirm substrate, formulation, reaction conditions and application before substitution.

Plasmid minipreps / 96-well silica-plate purification
96-well silica plates purify plasmid DNA with a separate lysate-clearance plate. Candidate for this workflow; follow the supplier protocol and validate input and instrument compatibility.

Plant DNA extraction / 96-well silica-plate purification
96-well silica plates purify plant genomic DNA after CTAB-based lysis. Candidate for this workflow; follow the supplier protocol and validate input and instrument compatibility.
Showing 24 of 503
Compare with context
ALTERNATIVE DOES NOT MEAN IDENTICAL
Final groups are designed around experimental substitution requirements. Group membership is provisional until the necessary technical details have been verified for the intended experiment.
Start with your application, then verify the technical requirements against each manufacturer’s documentation.
Broader catalog resources for this branch. These links are discovery starting points, not verified replacements for individual products.